Hello,
I am refining a low resolution data. According to
sigma vs. resolution, my resolution is 4.7A.
not sure what is "sigma vs. resolution" but hope you made the right
decision.
Because there are four identical molecular per
asymetric unit, I can use positional refinement. There are about
65% alpha-helices in the structure, so I want to use secondary
structure restrain. Does phenix has this restrain in the
refinement?
Sorry for missing documentation on this subject.
First of all, get the latest version of PHENIX (the one you have is
very old):
http://www.phenix-online.org/download/nightly_builds.cgi
Then (once you have the latest), yes, you can use secondary
structure restraints.
phenix.refine model.pdb data.hkl
main.secondary_structure_restraints=true
so phenix.refine automatically determines secondary structure
and applies the restrains. Note, GIGO principle applies, that is
if your input model is distorted then it's unlikely that the
procedure will figure out the secondary structure correctly.
To make it a less black-box, you can run
phenix.secondary_structure_restraints model.pdb >
ss_restraints.params
and then check (and edit if necessary) the ss_restraints.params file, and then run
phenix.refine as following:
phenix.refine model.pdb data.hkl
main.secondary_structure_restraints=true ss_restraints.params
I hope Nat comments more if I missed something.
Let me know if you have any other questions.
Good luck!
Pavel.