Dear all, I am currently refining a 1.9 A structure with PHENIX 1.10.1-2155. The problem I am facing is the following: Running the Molprobity server, it suggests me to correct a couple of N/Q/H flips. I perform the flips re-run PHENIX.REFINE with “Automatically correct N/Q/H errors” not ticked. The log file confirms the selection with nqh_flips = False. Nevertheless PHENIX.REFINE again flips these residues and the output PDB file has all previously flipped residues “re-flipped” in comparison to the input PDB file. I am very confident that the automatically flips performed by PHENIX.REFINE (REDEUCE) are wrong, since I have two metal binding sites. Why PHENIX.REFINE rotates side chains by 180 degree even though nqh_flips were set to false? Any help is appreciated. Cheers, Bernhard Dr. Bernhard Loll Freie Universitaet Berlin Fachbereich Biologie, Chemie, Pharmazie Institut fuer Chemie und Biochemie AG Strukturbiochemie Takustr. 6 D-14195 Berlin Germany Phone: +49 (0) 30 838-57348 Fax: +49 (0) 30 838-454936 Email: [email protected] Homepage: http://www.bcp.fu-berlin.de/chemie/bc/ag/agwahl/