Hi all,
I had a question about comparing structures based on RMSD comparisons vs e-/A^3. While the former seems to be more frequently used in structural studies with a standard value of 1.0 rmsd for 2Fo-Fc and 3.0 rmsd for Fo-Fc, there are differences in RMSD based on resolution. Hence, I wanted to ask if e-/A^3 could be a more appropriate comparison for looking at differences in electron density in a ligand-binding site between 2 structures of the same enzyme? So, here you would try and set e-/A^3 of all the maps (2Fo-Fc and Fo-Fc) to the same value.
The structures I’m referring to are between 2-2.5 angstroms in resolution.
I have also worked with the map sigma level comparison tool on PHENIX and wanted to know if that might be an alternate way to compare maps in 2 structures accordingly.
Regards,
Vatsal
Post-doctoral fellow, Davis Lab, Emory University
[email protected] | 346-719-9409