Have you seen: Iron–sulfur clusters have no right angles Nigel W. Moriarty and Paul D. Adams, Acta Cryst. (2019). D75, 16–20 http://journals.iucr.org/d/issues/2019/01/00/rr5165/index.html The Phenix F3S library worked well for our Complex II structures a few years back. And those structures definitely confirm that the angles are not 90* for F3S. (FES Fe2S2 has close to right angles, I think) You have to be sure that the atoms are arranged in the same way as in the model or the restraints will try to invert your cluster;, and that the Cys ligands connect to the right irons. Ed Rhys Grinter wrote on 4/18/2022 12:24 AM:
Hi PHENIX BB,
I'm currently refining a structure with 3Fe4S clusters into some high resolution cryoEM maps (1.57 Ang). However, refinement messes up the Fe4S cluster, by moving the existing Fe and S atoms into the wrong positions in the density.
Is anyone aware of this issue and/or knows of a simple way to prevent this from happening?
Cheers,
Rhys
-- Dr Rhys Grinter Lab Head Molecular Physiology of Microbial Pathogens (MP2) Lab Monash University +61 (0)3 9902 9213 +61 (0)403 896 767
_______________________________________________ phenixbb mailing list [email protected] https://urldefense.com/v3/__http://phenix-online.org/mailman/listinfo/phenix... Unsubscribe: [email protected]