Hi phenixer's
I'm in need of reliable f'/f'' for my heavy atom (that isn't Sasaki tables which I believe is for free, unbound atoms). I've used group_anomalous in phenix.refine before so I'm sure a phenix utility is capable of extracting it.
I wanted to if it's possible to extract it from several solved structures (I have the DANO/SIGDANO, F(+)/F(-), or if needed the original I(+)/I(-))
I'm curious to see if there's wide variation and whether it'd be as reliable (or even better) than actually taking a fluorescence scan (and of course use the values for my current phasing challenge as a starting point).