Deall all: I have a question about xray and neutron joint refinement. When I start phenix joint refinement like this, phenix gave the wrong message: phenix.refine dhfr-mtx-rt-xray.hkl neutron_data.file_name=newdhfr_un_change.hkl xn_easy_080326a.pdb input.xray_data.labels=FOBSx input.neutron_data.labels=FOBSn xray_data.r_free_flags.generate=True neutron_data.r_free_flags.generate=True refine_default.params ===================== joint neutron/xray refinement start ===================== Traceback (most recent call last): call_back_after_monitor_collect=call_back_after_monitor_collect) File "/usr/local/phenix-1.3-rc4/phenix/phenix/refinement/driver.py", line 1031, in run call_back_after_monitor_collect = call_back_after_monitor_collect) File "/usr/local/phenix-1.3-rc4/phenix/phenix/refinement/strategies.py", line 184, in refinement_machine * assert not neutron_refinement AssertionError* I guess in my default parameters, something is wrong, particularly the bold word I highlighted. But I do not know how to fix. Does any one have a clue?\ Thanks and Happy New Year! main { bulk_solvent_and_scale = True simulated_annealing = False ordered_solvent = False ncs = False ias = False number_of_macro_cycles = 3 max_number_of_iterations = 25 use_form_factor_weights = False tan_u_iso = False use_convergence_test = False target = *ml mlhl ml_sad ls min_number_of_test_set_reflections_for_max_likelihood_target = 50 max_number_of_resolution_bins = 30 reference_xray_structure = None use_experimental_phases = None compute_optimal_errors = False random_seed = 2679941 *scattering_table = wk1995 it1992 *n_gaussian neutron* use_normalized_geometry_target = True target_weights_only = False use_f_model_scaled = False max_d_min = 0.25 fake_f_obs = False -- Qun Wan Department of Pharmacology, Case Western Reserve University 10900 Euclid Avenue, Cleveland, OH 44106 email: [email protected] lab phone: 216-368-3337