Hi, please define "refinement still not working". I think phenix.refine wont accept UNX because it has undefined scattering type. Pavel On 5/22/20 13:41, Nigel Moriarty wrote:
Muhammad
There is an option in refinement that will determine the ion that best fits a density blob. You should try that after removing the UNX.
Cheers
Nigel
--- Nigel W. Moriarty Building 33R0349, Molecular Biophysics and Integrated Bioimaging Lawrence Berkeley National Laboratory Berkeley, CA 94720-8235 Phone : 510-486-5709 Email : [email protected] Fax : 510-486-5909 Web : CCI.LBL.gov http://CCI.LBL.gov
On Fri, May 22, 2020 at 1:27 PM Muhammad Bashir Khan
mailto:[email protected]> wrote: Hi there;
I find some unknown density in my map, where I put SO4 and in some UNX. I merged and save all in one PDB. I run ReadySet to make cif. file, but refinement still not working. Can anybody explain what else I should provide?
Thanks in advance
Bashir
-- ------------------------------------------------------ Muhammad Bashir Khan, Ph.D. Research Associate Department of Biochemistry Medical Science Bldg. Lab 3-27 University of Alberta Edmonton AB, T6G 2H7
Phone: 780-492-4577- e-mail: [email protected] mailto:[email protected] _______________________________________________ phenixbb mailing list [email protected] mailto:[email protected] http://phenix-online.org/mailman/listinfo/phenixbb Unsubscribe: [email protected] mailto:[email protected]