I meant that initially I did not have H in the refinement, sorry for the confusion.
By the way - should I still include "not (element H)" into the NCS parameters or it is done automatically. I used this line, but I am not sure if it is needed.
I will try the new built and report the results.
Thank you,
Tanya
On Fri, 2011-07-29 at 15:18 -0400, Tatyana Sysoeva wrote:Not sure what you mean by "including into refinement", but if it means
> when one includes hydrogens into a refinement of a model build with
> data at ~3.6A
that hydrogen positions are actually refined... well, you shouldn't do
that at 3.6A.
--
"Hurry up before we all come back to our senses!"
Julian, King of Lemurs
_______________________________________________