Hi,
Normally phenix.autobuild (I think phenix.refine is used in the refinement step of phenix.autobuild) will recognize the r_free_flag in the input data file (usually .mtz) whether in ccp4 convention or phenix convention. See document of autobuild, https://www.phenix-online.org/documentation/reference/autobuild.html#r-free-...
"In Phenix the parameter test_flag_value sets the value of the test set that is to be free. Normally Phenix sets up test sets with values of 0 and 1 with 1 as the free set. The CCP4 convention is values of 0 through 19 with 0 as the free set. Either of these is recognized by default in Phenix and you do not need to do anything special. If you have any other convention (for example values of 0 to 19 and test set is 1) then you can specify this with test_flag_value.
Note that phenix.refine and AutoBuild write out PDB files that contain the test_flag_value. AutoBuild can read this test_flag_value and use it automatically. However if there is a conflict between this test_flag_value and the default value based on your data file, you may have to specify which to use."
So I think the answer is YES.
Best!
Lu Zuokun
--
卢作焜
南开大学新生物站A202
Lu Zuokun, Ph.D. Candidate
College of Life Science, Nankai University
在 2016-05-12 16:01:09,"Luca Jovine"