Hi James, I'm sorry for the slow reply, I missed your email when you sent it and just saw it today. There are several ways you can try and get autobuild to build just a little more. One is just to put in the last model from the previous run in as model=mybestmodel.pdb and specify "rebuild_in_place=false" and run it again. In your case it sounds like you really want to fit a loop. Here is a good way to do that: phenix.autobuild data=mydata.mtz model=model_missing_loop.pdb \ input_map_file=map.mtz seq_file=sequence.dat rebuild_in_place=false \ include_input_model=true number_of_models=0 fit_loops=true \ connect=true build_outside=false insert_helices=False \ helices_strands_start=False n_cycle_rebuild_max=1 \ thorough_loop_fit=true number_of_parallel_models=1 Here the key parameters are fit_loops=true and skipping build_outside_model and insert_helices. The connect=true will help if you do not have sequence assigned at the ends of your loop. The thorough_loop_fit=true tell it to try hard for the loop. The number_of_models=0 says don't bother to rebuild the model from scratch. This should run relatively quickly. It is possible that it will "lose" some good parts of your model, so it may be necessary to do some splicing if that happens. All the best, Tom T Thomas C. Terwilliger Mail Stop M888 Los Alamos National Laboratory Los Alamos, NM 87545 Tel: 505-667-0072 email: [email protected] Fax: 505-665-3024 SOLVE web site: http://solve.lanl.gov PHENIX web site: http:www.phenix-online.org ISFI Integrated Center for Structure and Function Innovation web site: http://techcenter.mbi.ucla.edu TB Structural Genomics Consortium web site: http://www.doe-mbi.ucla.edu/TB CBSS Center for Bio-Security Science web site: http://www.lanl.gov/cbss On Mar 3, 2009, at 6:37 AM, James Whittle wrote:
Dear all,
AutoBuild has successfully built almost my entire model - I copied loops built better in one NCS copy to the other, and now only one 16 residue loop connecting two helices is missing. It initially built a chain through the density for this loop, but could not join it to the rest of the structure or place the sequence there, so I deleted it.
When I re-run autobuild on my modified model, rebuild_in_place=True is automatically set and this loop is not completed. The density is there, so it should be possible.
How does one instruct AutoBuild to finish an almost complete model (in particular this loop), without much change to the existing model?
--James _______________________________________________ phenixbb mailing list [email protected] http://www.phenix-online.org/mailman/listinfo/phenixbb