Hi Pavel, I also met the similar problem when refine my 6A data. I used the default setting in GUI. Xianchi
On Dec 9, 2014, at 21:35, Pavel Afonine
wrote: Hi Jianghai,
normally this shouldn't happen. I wonder what's going on.. Could you please send me inputs and I will have a look right away?
Thanks, Pavel
On 12/9/14 3:50 PM, Jianghai Zhu wrote: Hi all,
I recently solved a complex structure at 8 Å. There are 3 molecules per asymmetric unit and each complex contains 8 domains. I was trying to do rigid body refinement in phenix.refine. However, all the rigid body refinement gave me worse Rfree, even at ultra-low resolution, and phenix.refine reversed the result to the original model. Anyway to make this rigid body refinement more stable? Is there a dampen factor in phenix.refine so that the program only moves a domain at a fraction of what it wants to, e.g. 1/2, 1/3… ?
Thanks.
Best,
—Jianghai
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb