Dear Phenix users,
I refine a large complex with three monomers in ASU at very low
resolution - 4.5A - and would like to ask two questions.
- Could you give some tips about refinement at this resolution other
than rigid body refinement - Can TLS and grouped B-factors work at this
poor resolution ?
- I would really prefer that rigid body refinement will strictly obey
the NCS that was found in the molecular replacement solution. I
understand constrained NCS does not exist yet in phenix but is there
something approximate that can be used in rigid body refinement ? I
tried the conventional restrained NCS and the result was just like
without restrains.
Thank you for your time ,
Peter.