Hi Ezequiel, deviations are not unexpected in general but not that large as you report, so I wonder what's going on.. Could you please send me input data and model files, as well as any ligand files you used. If you customized some parameters, telling what were those would be helpful too. Please send all files off-list to my email directly. Thanks, Pavel On 12/6/15 22:36, Ezequiel Noguera wrote:
Hello, I'm working in a refinement that I started some time ago. I noted that repeating the same refinement task using a newer version of phenix, the refinement statistics Before and After refinement are different from values of the old version (I used "restore job" from the Job history to repeat the same task in the two versions installed in the same PC). Any explanation? I'm worried about the rms deviation. Thanks in advance.
new version: R-work: start=0.1697, final=0.1761 R-free: start=0.2011, final=0.2053 Bonds: start=0.046, final=0.029 Angles: start=1.321, final= 0.631
old version: R-work: start=0.1651, final=0.1657 R-free: start=0.2018, final=0.2009 Bonds: start=0.013, final=0.013 Angles: start=1.409, final= 1.411
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb Unsubscribe: [email protected]