Hi Yan,
are you sure that the space group is P4322. Although seen, it is less much likely that space groups with an additional screw axis such as P43212. Have you tried solving the structure in these alternatives - I'm not sure that Autosol will try all permutations. Also, you can use phenix.explore_metric_symmetry to see if there is any relationship between you tetragonal and orthorhombic lattices.
Cheers,
Paul
On Jun 23, 2013, at 8:52 AM, "赵岩"
Hi everyone,
The heavy atoms(Se-Met) were located at P4322 space group(4A). But the initial density map is so bad that I can not build the initial model.
Meanwhile, I have another two datasets, native(2.6A) and se-met anomalous dataset with space group P2221. But these two datasets have no solution. I have tried the initial map from sp P4322 as a model to do molecular replacement. But no MR solution.
So, I want to know how can I use the heavy atom as model to do MR with isomorphous or anomalous differences?
Thanks!
--
Yan Zhao, M.Phil. National Laboratory of Protein Sciences Institute of Biophysics Chinese Academy of Sciences 15 Datun Rd. Beijing, 100101 China _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb
-- Paul Adams Deputy Division Director, Physical Biosciences Division, Lawrence Berkeley Lab Division Deputy for Biosciences, Advanced Light Source, Lawrence Berkeley Lab Adjunct Professor, Department of Bioengineering, U.C. Berkeley Vice President for Technology, the Joint BioEnergy Institute Laboratory Research Manager, ENIGMA Science Focus Area Building 64, Room 248 Building 80, Room 247 Building 978, Room 4126 Tel: 1-510-486-4225, Fax: 1-510-486-5909 http://cci.lbl.gov/paul Lawrence Berkeley Laboratory 1 Cyclotron Road BLDG 64R0121 Berkeley, CA 94720, USA. Executive Assistant: Louise Benvenue [ [email protected] ][ 1-510-495-2506 ] --