Hi All
I was just going through the .help section and website documentationfor ordered_solvent. And wonder if somebody could enlighten me as toothe meanings of;
ordered_solvent {primary_map_type = mFobs-DFmodelsecondary_map_type = 2mFobs-DFmodelh_bond_min_mac = 1.8h_bond_min_sol = 1.8h_bond_max = 3.2}peak_search {map_next_to_model {use_hydrogens = False}max_number_of_peaks = Nonepeak_search {peak_search_level = 1max_peaks = 0interpolate = Truemin_distance_sym_equiv = Nonegeneral_positions_only = Falsemin_cross_distance = 1.8}
What is the difference between the primary and secondary map? Is thereaway to pick sites in one and remove in another? Eg. pick sites at 3 sigmain FoFc and remove if 1.2 sigma in 2FoFc.
I thought h-bonding was generously about 2.4-3.6A so why the 1.8 and 3.2defaults? Also if use_hydrogens = True, does the refinement use h_bondparameters instead of model_peak_dist and peak_peak_dist parameters, orboth? Also what do all of the peak_search parameters do?
And finally does anyone have any recommendations for progessively changingthe ordered_solvent parameters? In CNS we used to gradually lower the2FoFc peak picking (and deleting) and increase the bfactor_max fordeleting?
Thanks Mark
_______________________________________________ phenixbb mailing list phenixbb@phenix-online.org http://www.phenix-online.org/mailman/listinfo/phenixbb