None of those.  In phenix, anisotropic individual ADPs will be refined at high resolution (better than 1.5 Å resolution by default).  In the GUI, this limit is set under Global Refinement Parameters > Resolution Limit for automatic anisotropic ADPs.

Best wishes
kmj

On Fri, Feb 20, 2015 at 2:07 AM, Smith Lee <smith_lee123@yahoo.com> wrote:
Dear All,

For TLS, the document says,

"Can I use both TLS and anisotropic ADPs?
Yes, but not for the same atoms - since TLS is essentially constrained anisotropic refinement, the two methods are mutually exclusive".

In the "Refinment settings" of the Phenix refine graphical interface, will you please tell me which button is for the anisotropic ADP? The individual B-factors, or the Group B-factors, or only the "Optimize X-ray/ADP weight"?

I am looking forward to getting your reply.

Smith

_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb
Unsubscribe: phenixbb-leave@phenix-online.org