Try updating to phenix 1.3-final to see if the problem has been fixed. On Sep 25, 2008, at 11:53 AM, Jianghai Zhu wrote:
Hi,
I got the following error from phenix.refine version 1.3-rc4.
iotbx.reflection_file_utils.Sorry_Not_a_suitable_array: Not a suitable array of experimental phases: refineme nt.input.experimental_phases.labels=HLAM,HLBM,HLCM,HLDM
What is the problem?
-- Jianghai
_______________________________________________ phenixbb mailing list [email protected] http://www.phenix-online.org/mailman/listinfo/phenixbb
-- Paul Adams Deputy Division Director, Physical Biosciences Division, Lawrence Berkeley Lab Adjunct Professor, Department of Bioengineering, U.C. Berkeley Vice President for Technology, the Joint BioEnergy Institute Head, Berkeley Center for Structural Biology Building 64, Room 248 Tel: 1-510-486-4225, Fax: 1-510-486-5909 http://cci.lbl.gov/paul Lawrence Berkeley Laboratory 1 Cyclotron Road BLDG 64R0121 Berkeley, CA 94720, USA. Administrator: Kristine Sawyer [ [email protected] ][ 1-510-486-4151 ] --