Hi Nat,

It seems that the text editor of mac is not recognized by phenix as its not in ASCII format. I could input the file when I saved it in notepad from windows. Thanks a lot for the help. 

I also want to know whether its possible to assign the charge of the metal in the chelator complex, or is it ignored in refinement.

Thanks
Subhani

On Thu, Feb 2, 2012 at 9:16 AM, Nathaniel Echols <nechols@lbl.gov> wrote:
On Thu, Feb 2, 2012 at 6:56 AM, Subhani Bandara <ramssb17@gmail.com> wrote:
> Am I doing anything wrong and is there any other way to fix the distances of
> the metal chelator complex.

I should have mentioned that there are at least three other ways to do
what you want:

1) in the GUI, run ReadySet (available from the phenix.refine toolbar)
to generate the metal coordinate distances (which will be
automatically loaded for you)
2) also in the phenix.refine GUI, but only in the latest nightly
builds, there is an editor for custom restraints
3) on the command line, phenix.metal_coordination (or
phenix.ready_set, but that does other stuff too)

-Nat
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb