Dear Nat,
You are right.
I added two metal ions Zn and Mg and after that I started getting this error.
I did run phenix.metal_coordination to get elbow.edits and add this to refinement to to get same error.
I am not running with water update option.
I ran the pdb through readyset and added metal restraints, processed pdb file and ligand restraints to the refinement to get same error.
The Zinc and Mg are not coordinated well. I have added because nothing fits in the density. I am not sure lack coordination is creating the problem. I will send ATOM records to Pavel.
Thanks a lot for looking in to this one.
SDY
From:
[email protected]Date: Tue, 4 Mar 2014 07:50:31 -0800
Subject: Re: [phenixbb] phenix error
To:
[email protected]CC:
[email protected]You probably have metal coordination restraints that are no longer valid - each time you run phenix.refine with the solvent update enabled, the numbering of waters will change and the old restraints become invalid. �The utilities menu in the phenix.refine GUI has an option to clear these out entirely; you can then run ReadySet again to generate new restraints.
-Nat