Are you talking about the "auto fit rotamer" function? I am not using that. I tend to select rotamers from the list but I rarely pic the auto one (it tends to place my side chains inside the neighbouring main chain densities most of the time). 

Mario Sanches

On Thu, Apr 19, 2012 at 9:06 AM, Nathaniel Echols <nechols@lbl.gov> wrote:
On Thu, Apr 19, 2012 at 8:00 AM, Mario Sanches <mariosan@gmail.com> wrote:
> I see regions with bad clashes solely because during refinement a side chain
> is being fit into a density peak that is to close to another residue atoms.
> I wonder if there is a way to tell the program to avoid clashes even if it
> is at the expense of real-space fitting?

Are you using the automatic rotamer correction?  This performs poorly
at low resolution - 2.9A is about the point where it really breaks
down.

-Nat
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb



--