Hi Owen, to be sure, try both and check the .log file - this will avoid guesswork. However, I think "I1-" should work. Pavel. On 7/14/10 2:22 PM, Owen Pornillos wrote:
Thanks! Just to clarify, should I define the iodide as "I-" or "I1-" in the PDB file?
Owen
On Jul 14, 2010, at 5:19 PM, Pavel Afonine wrote:
Hi Owen,
no, it's not the case anymore: phenix.refine uses the charge, and this is available in phenix build 1.6.1-343 or higher. The charge must be defined in PDB file:
Example:
HETATM 711 ZN ZN A1400 -1.928 -11.394 -27.827 1.00 17.21 ZN2+
To be sure it works, in the phenix.refine output, look for:
Number of scattering types: 6 Type Number sf(0) Zn2+ 2 28.00 <<<<<< HERE S 13 16.00 Na 2 11.00 O 240 8.00 N 113 7.00 C 442 6.00 sf(0) = scattering factor at diffraction angle 0.
Pavel.
On 7/14/10 2:04 PM, Owen Pornillos wrote:
Hi BB,
I am refining a structure that contains iodide ions. I remember some previous posts that PHENIX does not take into account the charge state and uses scattering factors for neutral atoms only. Is this still true?
Thanks,
Owen
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb