Hi Pavel,
One of the bond angles in the sulphonamide groups SO2NH2 was not correct so had to go into the cif file to correct the bond angle, in another instance -CN bond angles were getting smaller than 180 degree (right after one round of refinement in phenix) however i was told that these issues have been taken care of in the recent version of phenix.
I will double check my refmac generated cif file and try running phenix refine according to Nigels suggestion.
thanks,
shya
Hi Shya,
can you explain what exactly the issue is with the elbow generated CIF file in your specific situation?
Yes, SMILES string is a better input for elbow than PDB.
Pavel
On 1/22/12 6:35 PM, Shya Biswas wrote:
Hi all,
It appears that the cif file generated from prodrg (REFMAC format) is not recognised by phenix during refinement. Did anyone have similar issues or i am doing something wrong? somehow the geometries obtained from elbow are not right for my ligand so had to use prodrg to generate cif files.
thanks,
Shya
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb