Hi Engin, thanks for understanding! I will think some more of what we can do in future to facilitate the issues like this. My hope is that if I add a map CC as an additional filtering criterion then it might partially resolve this issue (which I will do soon) but of course there is no guarantee ... Pavel. On 3/8/09 9:52 PM, Engin Ozkan wrote:
Thanks Pavel, you are as prompt and helpful as always.
I agree that fixing waters sounds like a very, very bad idea. I am only thinking of adding restraints for waters coordinating metals (with appropriate sigma), where water-metal distance can easily get down to 2 A (A possibly bigger issue that I haven't given much thought to might be that such a water ends up being very close (~3.2-3.5 A) to four more metal-coordinating oxygens; that may look impossible from a hydrogen bonding water point-of-view). Playing with water selection criteria would have global effects, quite significant in a structure with 800 water molecules (as of yet). I think I'll stick with what I was doing, or maybe add a last ordered_solvent=False to the refinement at the end.
Engin
Pavel Afonine wrote:
Hi Engin,
Sorry for the inconvenience...
Water molecules are treated slightly different in phenix.refine than the other atoms. For example, you cannot preserve a specific water molecule: it it falls outside a selection criterion (distances, peak heights, etc...), than it will be removed anyway.
The only way to preserve your favorite waters is:
- either turn water picking off: ordered_solvent=false - or do what you did: rename it somehow so phenix.refine "don't think" that it is water.
None of the above options sound attractive to me but this is how it is right now.
There are pros and cons for this approach and there was a discussion about it a few months ago. In the end I agreed that we need an option to preserve "user's favorite" waters. It is in my list, implementing it may take some time - it's not very straightforward. In general, the whole water picking procedure in phenix.refine needs some review (for example, use map CC as additional criterion, etc...). Although I still don't like the idea for fixing waters: what if the user fixes a water that later on in refinement proves to be noise peak and so its B-factor jumps sky high, it moves somewhere, etc, but phenix.refine will not be able to remove it since the user ordered to not do so... Could you rather play with selection criteria so your waters stay?
Pavel.
On 3/8/09 4:02 PM, Engin Ozkan wrote:
Are restraints on water molecules overwritten on successive cycles of refinement where ordered solvent is on? I seem to lose my distance restraints between specific waters and metal, unless I name my water molecules something else (and supply phenix with a cif for that name which is identical to water inside). The distance restraints also seem to be in effect for all cycles if ordered_solvent is off. I am also trying to make sure water numbers don't change during solvent picking/deleting.
Engin _______________________________________________ phenixbb mailing list [email protected] http://www.phenix-online.org/mailman/listinfo/phenixbb
_______________________________________________ phenixbb mailing list [email protected] http://www.phenix-online.org/mailman/listinfo/phenixbb