Hi James,

Yes, that is correct.

However if you want...you can just go on to AutoBuild and build a new model from scratch and generate a set of free R flags there, supplying your data as data=mydata.sca. I would recommend this anyway because AutoBuild makes a much better model than AutoSol, and including the model from AutoSol doesn't necessarily help (and can make it worse if the AutoSol model is really incomplete, such as from secondary-structure-only model-building). I use the AutoSol model-building just to see if things are going well and then I throw that model away.  This is also the default when you use "after_autosol=True" in AutoBuild and when you run the AutoBuild GUI after running AutoSol. It is convenient to use the data and freeR in in exptl_fobs_phases_freeR_flags_*.mtz from AutoSol but you don't have to.

The key of course is:  once you refine a model and want to use that model further...you must use the set of free R flags used in that original refinement from then on.  If you throw away that model and start from scratch you can also make a new set of free R flags. The hexdigest REMARK in your PDB file from phenix.refine helps you make sure that this is done correctly.

All the best,
Tom T

On Jul 9, 2009, at 8:35 AM, James Whittle wrote:

Dear Tom:

Ok. Thanks for the quick response!

I should run then run AutoSol again to get this file, and it will have the HL coefficients in it?

--James


On Jul 9, 2009, at 10:13 AM, Tom Terwilliger wrote:

Hi James,

As you are expecting, in AutoSol the file exptl_fobs_phases_freeR_flags_*.mtz normally contains the experimental Fobs and free R flags for refinement, along with phases and HL coefficients from the experimental phasing. 

However if an anisotropy correction is applied to the data, then by default no refinement is done in AutoSol and no exptl_fobs_phases_freeR_flags_*.mtz file is created.  This is to ensure that refinement is not carried out against anisotropy-corrected data (you want to refine against the original data, and have phenix.refine apply an anisotropy correction as part of refinement).

If you supply 

input_refinement_file=my_data.sca 

then my_data.sca will be used for refinement and an exptl_fobs_phases_freeR_flags_*.mtz will be created.  Note that my_data.sca can be identical to your input data file if you want.  I am guessing that in your case an anisotropy correction was applied to the data in this way.  

I hope that helps!
-Tom T
ps. I am thinking of changing the default to make input_refinement_file automatically defined if an anisotropy correction is applied so that you don't have to do this...

On Jul 9, 2009, at 7:55 AM, whittle wrote:

Dear all,

I have a question regarding the output of AutoSol.

I've run AutoSol, using the data directly from scalepack as a .sca file,
and would like to now begin refining the structure I've built.

There seems to be no exptl_fobs_phases_freeR_flags_*.mtz file in the
AutoSol directory. Isn't this the right file to use? Since it's not
there, is it proper to use the phaser_2.mtz file for phenix.refine?

--James

_______________________________________________
phenixbb mailing list
[email protected]
http://www.phenix-online.org/mailman/listinfo/phenixbb


Thomas C. Terwilliger
Mail Stop M888
Los Alamos National Laboratory
Los Alamos, NM 87545

Tel:  505-667-0072                 email: [email protected]
Fax: 505-665-3024                 SOLVE web site: http://solve.lanl.gov
PHENIX web site: http:www.phenix-online.org
ISFI Integrated Center for Structure and Function Innovation web site: http://techcenter.mbi.ucla.edu
TB Structural Genomics Consortium web site: http://www.doe-mbi.ucla.edu/TB
CBSS Center for Bio-Security Science web site: http://www.lanl.gov/cbss




_______________________________________________
phenixbb mailing list
[email protected]
http://www.phenix-online.org/mailman/listinfo/phenixbb



Thomas C. Terwilliger
Mail Stop M888
Los Alamos National Laboratory
Los Alamos, NM 87545

Tel:  505-667-0072                 email: [email protected]
Fax: 505-665-3024                 SOLVE web site: http://solve.lanl.gov
PHENIX web site: http:www.phenix-online.org
ISFI Integrated Center for Structure and Function Innovation web site: http://techcenter.mbi.ucla.edu
TB Structural Genomics Consortium web site: http://www.doe-mbi.ucla.edu/TB
CBSS Center for Bio-Security Science web site: http://www.lanl.gov/cbss