On Sep 11, 2009, at 3:54 PM, Pavel Afonine wrote:
I have Zn atoms in my pdb for refinement. However, it failed with
the following scripts. Do I have to create a libary of this heavy
atom?
no, you shouldn't. Zn should be recognized automatically if it is
properly defined in input PDB file. I just verified that if it is
formatted like this:
HETATM 2306 ZN ZN D 1 24.598 75.945 -1.390 1.00
5.00 ZN
then it works fine. I'm not sure if capitalization is important as
well as HETATM instead of ATOM - this is something you can try in no
time.
I'm pretty sure capitalization is indeed important, because I had a
similar problem in both phenix.refine and eLBOW with manganese (MN is
okay, Mn is not).
-------------------
Nathaniel Echols
Lawrence Berkeley Lab
510-486-5136
[email protected]
_______________________________________________
phenixbb mailing list
[email protected]
http://www.phenix-online.org/mailman/listinfo/phenixbb