On Thu, May 26, 2011 at 8:53 AM, Christian Roth <christian.roth@bbz.uni-leipzig.de> wrote:
I am sorry for this very stupid question, but I probably overlooked the
relevant text in the documentation. I requested the refinement of a heavy atom
(chloride) with anisotropic ADP. In the log than isotropic refined ADP were set
for 0 atoms. I guess I have to define all other chains as isotropic. Is that
right. I have a lot of chains, it would be possible but a pain (more than 40
chains). Is there a something like refine anisotropic chain x and all others
isotropic?

You could set the anisotropic selection to "element CL" and the isotropic selection to "not (element CL)".

However, in theory if you explicitly set the anisotropic selection, by default everything else will be isotropic, so I'm not sure why it says 0 atoms - could you please send the log file to help@phenix-online.org (not the list)?  Were you using the GUI or the command line?