Hi Yarrow,
oh good! I'm glad you solved the problem -:)
All the best,
Pavel
On 6/18/14, 8:02 AM, Yarrow Madrona wrote:
Hi Pavel,
Thanks for your quick response. It turns out that after I reprocessed a data set in a higher symetry space group I forgot to use a reference mtz so the orientation was completely off. I just re-ran phaser and everything worked fine. I didn't run rigid body refinement after phaser.
The original error message didn't list the atoms and I am not sure how it could have any atoms on special positions with the solution being completely wrong. Probably nothing to worry about.
-Yarrow
On Tuesday, June 17, 2014, Pavel Afonine <pafonine@lbl.gov> wrote:
Hi Yarrow,
ok, I wish that error message (that I put a while ago, in 2009 to be precise) lists those atoms... Can you send me the file so I can tell you what these atoms are?
In general, if at rigid-body refinement stage you have atoms at special positions it is unlikely to be right.
Pavel
On 6/17/14, 12:56 PM, Yarrow Madrona wrote:
Hi,
I am trying to do rigid body refinement, however I get an error in phenix telling me that there are atoms at special positions.
I am not sure how to determine which atoms are at special positions so that I can exclude them from rigid body refinement. Can someone help me with this? Thank you.
-Yarrow