Can you send the residues involved?

Nigel

NB. Any files sent to me will be held in strictest confidence.



On Mon, Sep 30, 2013 at 12:51 PM, Zhang yu <phenixzyfish@gmail.com> wrote:
Hi everyone,

My structure contains a metal coordinating to some residues, one of which has alternative conformations. Phenix doesn't pickup the residue with alternative conformation when I tried to generate metal restrains using ready.set.

Any idea? Thanks

Yu 

_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb




--
Nigel W. Moriarty
Building 64R0246B, Physical Biosciences Division
Lawrence Berkeley National Laboratory
Berkeley, CA 94720-8235
Phone : 510-486-5709     Email : NWMoriarty@LBL.gov
Fax   : 510-486-5909       Web  : CCI.LBL.gov