On Thu, Jun 16, 2011 at 1:26 PM, Louis Lazar
On Thu, Jun 16, 2011 at 4:18 PM, Nathaniel Echols
wrote: On Thu, Jun 16, 2011 at 1:07 PM, Louis Lazar
wrote: Second, when I try to real space refine any of the residues, I get an error message telling me about exploding atoms. What is the cause of this message, and is it possible to real space refine any of these residues and specifically the hydrogen atoms associated with them.
Quick question - are the atoms exploding in Phenix, or in Coot?
Coot
Okay, this is a conflict between the monomer library distributed with Coot, which uses the old PDB v2 standard for hydrogen names, and what Phenix does, which is to use PDB v3 hydrogens. I think you can get around this problem by telling Coot to use the newer CCP4 monomer library, which also uses v3. Unfortunately, I'm not sure where to get this or how to configure it, although I'm pretty sure it involves setting an environment variable. Perhaps Paul Emsley (or someone else who has run into the same problem) could comment? -Nat