27 Jun
2009
27 Jun
'09
5:28 p.m.
Hi Maia,
I made all restraint_groups in my parameter file. It's just too many of them. I thought that may be there is an option to say exclude residues 125, 248 etc.
No - there is no such command: you need to edit selections manually.
By the way, I have excessive_distance_limit = None. If I change it to some number, how does it work? the violating residues will be excluded or the whole molecule will?
I'm not sure, Ralf knows this better. Ralf, could you comment on this please? My guess, that all this parameter does is it checks the distances between atoms in NCS copies and if there is a distance larger than excessive_distance_limit, then phenix.refine stops and tells you this. Pavel.