Hi Ricardo,
I'm sorry, yes you do have to supply a sequence file for local sharpening.
I will fix the documentation. If you want you can just put in a dummy
sequence and supply a value for "solvent_content=xxx" and that will
accomplish the same thing.
Let me know if that doesn't do it!
all the best,
Tom T
On Thu, Jan 18, 2018 at 1:42 PM, Ricardo Righetto wrote: Hi, I am trying to do local sharpening with phenix.auto_sharpen, with the
following command: phenix.auto_sharpen map.mrc resolution=4.0 local_sharpening=True Then it runs the global sharpening first as expected, but when it gets to
the local sharpening it crashes with the following error: Sorry: Please specify a sequence file with seq_file=myseq.seq Nowhere it says that I would need a .seq file in order to do local
sharpening (global sharpening works fine). Any ideas? Thanks, --
Ricardo Diogo Righetto _______________________________________________
phenixbb mailing list
[email protected]
http://phenix-online.org/mailman/listinfo/phenixbb
Unsubscribe: [email protected] --
Thomas C Terwilliger
Laboratory Fellow, Los Alamos National Laboratory
Senior Scientist, New Mexico Consortium
100 Entrada Dr, Los Alamos, NM 87544
Email: [email protected]
Tel: 505-431-0033