Hi,
I am forwarding your question to the cryo-Fit developers.
Best wishes,
Dorothee
On Tue, Feb 9, 2021 at 11:50 AM Reza Khayat
Hi,
The gaussian filter used to prepare cryo-EM maps for cryo_fit is equivalent to a low pass filter. Can anyone suggest a resolution to low pass filter the map to? Or is this value empirically determined by screening through a number of resolutions? Thanks.
Best wishes,
Reza
Reza Khayat, PhD Associate Professor City College of New York Department of Chemistry and Biochemistry New York, NY 10031 _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb Unsubscribe: [email protected]
-- Research Scientist, Molecular Biophysics and Integrated Bioimaging Lawrence Berkeley National Laboratory 1 Cyclotron Road, M/S 33R0345 Berkeley, CA 94720 Tel: (510) 486-5709 Fax: (510) 486-5909 Web: https://phenix-online.org