Pavel Afonine wrote:
  
    
Hi,
    
phenix.refine model.pdb data.mtz main.ncs=true
    
will do refinement with NCS restraints. The NCS groups will be
determined automatically. It may be important to check the automatic
choice.
See phenix.refine manual for details:
    http://phenix-online.org/documentation/refinement.htm#anch24
    
Also, at this resolution you may consider using TLS and/or group ADP
refinement. 
    
phenix.refine does not have NCS constrains, which I believe you do not
need at this resolution.
    
Pavel.
    
    
  
  Hi Pavel,
  
   Got to disagree with you on this one.  Depends on your obs to
params.  If youve 
   got 90% solvent then perhaps.......I would always favour reducing my
params by 
   a factor of 5 at 3.6Angs.
  
  Jon  
  
  PS  Any plans for coding up NCS constraints !!!    ;-) 
  
  
  
  -- 
Dr. Jonathan M. Grimes,   
University Research Lecturer
Division of Structural Biology
Wellcome Trust Centre for Human Genetics
University of Oxford
Roosevelt Drive,
Oxford OX3 7BN, UK
Email: Jonathan@strubi.ox.ac.uk, Web: www.strubi.ox.ac.uk 
Tel: (+44) - 1865 - 287561, FAX: (+44) - 1865 - 287547       
  
  
  
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org