Quick fix:  use autoindex_override_deltaphi=0.8 on the labelit.index command line.

Nick

On Sun, Apr 1, 2012 at 10:08 PM, <fukamitka@chugai-pharm.co.jp> wrote:
Dear Phenix developers,

I had a problem in indexing by labelit.index in phenix-1.7.3-928,
getting the error below:

InputFileError: Input error: All images must have same oscillation range (delta phi).

My dataset was collected by inhouse R-axis with 0.8 deg oscillation.
Image header values of oscillation range fluctuate between 0.799999 - 0.800004 degrees.
When I specified two images whose delta phi angles were different,
say 0.799999 and 0.800003, labelit.index stopped with the error above.

I don't think a goniometer have such a precision, therefore I think line 249
in /phenix-1.7.3-928/labelit/command_line/imagefiles.py should be modified
not to use == instead of similar_delta_phi() or something.

 246   if False in [similar_wavelength(self.images[0],self.images[x]) for x in xrange(1,Nimages)]:
 247     raise InputFileError("""All images must have similar wavelength.""")
 248
 249   if False in [self.images[0].deltaphi==self.images[x].deltaphi for x in xrange(1,Nimages)]:
 250     raise InputFileError("""All images must have same oscillation range (delta phi).""")

Best regards,

Takaaki Fukami

-----
Dr. Takaaki Fukami (mailto:fukamitka@chugai-pharm.co.jp)
Discovery Research Dept. (Biostructure Gr.)
Roche Group: Chugai Pharmaceutical Co.,Ltd.

_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb



--
Nicholas K. Sauter, Ph. D.
Computer Staff Scientist, Physical Biosciences Division
Acting Head, Berkeley Center for Structural Biology
Lawrence Berkeley National Laboratory
1 Cyclotron Rd., Bldg. 64R0121
Berkeley, CA 94720-8118