On Nov 2, 2009, at 3:38 AM, Felix Frolow wrote:
I try to use a shiny new GUI for Phaser I stuck with the definition of a component mass. Line command accept "None" for mass of component, but not GUI. It claims that the mass calculated value I supply is not integer number, for the sake of argument I have tried 14, 14.0 etc. (BTW as a sequence is also supplied, why just not to calculate it?).
Just to clarify for the list, there is a new AutoMR GUI in the current nightly builds. (Not for Phaser itself - that's on the to-do list.) It will feed results directly to AutoSol if you are trying to phase with MR-SAD. Felix already figured out the answer, but it's a little confusing: AutoMR (like Phaser) is flexible about how you specify the component mass, but you can only use one source of information - defining both the sequence and the mass will result in an error message. More generally, in the GUI 'None' (which is really the standard Python null value, not some Phenix-specific keyword) is translated to a blank string, so if you want to set a parameter to None, just leave the field blank. -Nat ------------------- Nathaniel Echols Lawrence Berkeley Lab 510-486-5136 [email protected]