Hi Daniel,

We don't have a standard way to interpret the R value for density modification...hence the rough guide of "0.25 is good and 0.5 is poor" but no documentation.  This applies to both X-ray and cryoEM density modification.

This R value describes the mismatch between measured and map-based structure factor amplitudes.  Usually these match pretty well in cases where the map is improved a lot and not when the map does not improve, but there is no obvious and simple relationship. 

My recommendation would be to use the estimate of map resolution and visual quality as your guide as to whether it has improved your map, and the R value in density modification as a possible indication that some change of parameters might help if things are not going well (not that it tells you what to change, but a good one is always resolution and another is solvent content.)

In your case I might try cutting the resolution or randomly changing solvent content and testing...but as the map looks ok I would not try too hard.

I hope that helps!
All the best,
Tom T

On Wed, Jun 8, 2022 at 14:25 Daniel Larsson <daniel.larsson@icm.uu.se> wrote:
Hi all,

I tried to do density modification using the resolve_cryo_em tool. The resolution improves quite a lot from around 2.60 to around 2.35 and the density looks significantly better than the autorefined original map. However, the R-values is close to 0.5, which seems very high. How should the R-value generated by this tool be interpreted? It is very poorly documented and not mentioned in the paper or on the manual page, but Tom Terwilliger mentioned in a workshop that “low number is good” and “point two-four is a very good number, point five is not a good number”, which makes me worried.

Regards,
Daniel









När du har kontakt med oss på Uppsala universitet med e-post så innebär det att vi behandlar dina personuppgifter. För att läsa mer om hur vi gör det kan du läsa här: http://www.uu.se/om-uu/dataskydd-personuppgifter/

E-mailing Uppsala University means that we will process your personal data. For more information on how this is performed, please read here: http://www.uu.se/en/about-uu/data-protection-policy

_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb
Unsubscribe: phenixbb-leave@phenix-online.org
--
Thomas C Terwilliger
Laboratory Fellow, Los Alamos National Laboratory
Senior Scientist, New Mexico Consortium
100 Entrada Dr, Los Alamos, NM 87544
Tel: 505-431-0010