Dear all, 
                    
                  
                  I am refining my structure (data at 3 A), with a model
                  that is complete. However the Rs values are: R work=
                  0.25 and Rfree= 0.32. I have read "Improved target
                  weight optimization in phenix.refine" (In the
                  computational crystallographic newsletter 2011) and
                  what I understand is that just by marking the boxes
                  "improve xray/stereochemistry weight" and "improve
                  xray/adp weight" it should work... giving me the best
                  possible Rfree. 
                  
                
 
                I'm refining individual coordinates, occupancies,
                b-factors (isotropic for all atoms), TLS, and using
                secondary structure restraints, automatic ligand linking
                and experimental phases restraints. Also, I chose this
                strategy because I have finished building the structure
                and according to some of the suggestions in "towards
                automated crystallographic structure refinement with
                phenix.refine".
                
              
 
              I am actually quite confused and don't know what to
              think... is it a matter of the weights? is it only that
              this is as good as it gets?