Starting AutoSol with the command:
phenix.autosol data=ScalAveragedSG_76_30.ref
seq_file=seq_from_pdb.dat \
refine_eff_file_list=./refinement/non_default.eff sites=2
atom_type=I \
f_prime=-0.582314 f_double_prime=6.84299 res_phase=3.4
resolution_build=3.0 \
resolution=3.0 wavelength=1.5418 ha_sites_file=./ha_sites.pdb
Sending output to AutoSol_run_7_/AutoSol_run_7_1.log
********************************************************************************
Failed to carry out AutoSol_build:
Refinement failed...perhaps something wrong with input refinement file
or data file or the column labels for them?
Error message from phenix.refine:
Empty atom selection:
refinement.refine.anomalous_scatterers.group.selection="name I"
********************************************************************************
Cuts out in the first round of refinement (after initial Build_1.pdb) .
I guess I should not have specified anomalous scatterers (at least to
autosol).
Does it refine anomalous automagically in the autobuild when doing a
SAD via autosol?
How do I recover from this error? (continue with the autobuild
without anomalous scattering it now seems).
Thanks
FR
---------------------------------------------