You probably have metal coordination restraints that are no longer valid -
each time you run phenix.refine with the solvent update enabled, the
numbering of waters will change and the old restraints become invalid. The
utilities menu in the phenix.refine GUI has an option to clear these out
entirely; you can then run ReadySet again to generate new restraints.
-Nat
On Mon, Mar 3, 2014 at 10:31 PM, SD Y
Hi,
Could you please tell me why am I getting this error " No atom selected: "name O and chain W and resname HOH and resseq 69".
Log file ends as follows:
============================= Scattering factors =============================
----------X-ray scattering dictionary----------
Number of scattering types: 7 Type Number sf(0) Gaussians Zn2+ 1 27.88 1 S 10 15.96 2 P 2 14.95 2 Mg2+ 3 9.96 1 O 635 7.97 2 N 523 6.97 2 C 1983 5.97 2 sf(0) = scattering factor at diffraction angle 0.
========================== Anomalous scatterer groups =========================
All atoms refined with f_prime=0 and f_double_prime=0.
======================== Summary of geometry restraints =======================
Number of disulfides: simple=0, symmetry=0 Custom bonds: Sorry ------------------------------
Thanks a lot SDY
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb