-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Dear Smith, in case you irradiated your crystal with electrons during data collection you may notice a slight improvement in the model quality if you choose the electron scattering table. Otherwise, if you think that the scattering is mostly due to the impact of X-rays onto your crystal it it safe to stay with the default options. Best regards, Tim On 04/01/2015 03:23 AM, Smith Liu wrote:
Dear All,
For the Phenix refine, the default for the Scattering table in "other options" in the graphical interface is n_gaussian, in which situation to use electron is much better? And how much would be the benefit to use electron instead of n_gaussian?
Smith
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb Unsubscribe: [email protected]