Use the following option on the phenix.refine command line
main.nqh_flips=False
That will prevent automatic residue flipping
Oleg Borbulevych
-----Original Message-----
From: "Vikram Dalal"
Sent: Thursday, January 19, 2017 5:36am
To: [email protected]
Subject: [phenixbb] help with Histidine flip in phenix refinement
_______________________________________________
phenixbb mailing list
[email protected]
http://phenix-online.org/mailman/listinfo/phenixbb
Unsubscribe: [email protected] all,
I have 4 Mn (2 Mn in each chain) in my protein structure. One Mn has 1
cordination with water, 1 cordination with His and 4 cordination with Asp.
I model build the His in coot. Even this His is in bond range with Mn. But,
when i refine this model in phenix. This His again flip other side (N
terminal which has to cordinate with Mn goes to other direction). I am
facing this problem only with His of A chain only while N of His of B chain
are towards Mn only.
Is there any option in pehnix refinment where we can exclude a specific
residue or atom in refinment??