Thanks for the e-mail!
I think I've figured out the problem. I had been using the GUI to set "input_map_file" and "input_map_labels" rather than using "Optional map coefficient file name". It wasn't reading in the solvent flattened data correctly (and thus not setting "phases_from_resolve").
In addition there seems to be a bug in how the optional map file labels are read, since:
temporary.com:LABIN FP=PHIdm PHIB=FOMdm FOM=Fdm
Is there a fix for this (version 1.3), as I've flipped them round and still get them mis-assigned?
Cheers!
Hi Mo,
There isn't any place in the AutoBuild GUI specifically for
"phases_from_resolve". If you really want to set this parameter you can
go to the "uncommon inputs" window and set "resolve_command" to
"phases_from_resolve".
I think that you don't want to do this, however. I am assuming that this
means that you are using a density-modified map as input to AutoBuild with
data=my_density_modified_map.mtz.
What you want to do instead is say (or set in the GUI):
data=my_experimental_fobs_and_phases.mtz \
input_map_file=my_density_modified_map.mtz
and then AutoBuild will start from your density modified map, but it will
use experimental phase information as the prior phase information. It will
also automatically set the parameter "phases_from_resolve" so that that
you do not have to.
I hope that helps!
-Tom T
_______________________________________________
Hi all,
Can someone tell me where in the AutoBuild GUI I can set
"phases_from_resolve"? I've looked for it in the "set variable" section,
but
it's not listed.
Thanks!
phenixbb mailing list