Hi Mark, I think it depends who is handling your deposited pdb file recently I submitted a file with hydrogen added and had no problems. My resolution was 1.8A. Shya
Here's one for the community, which I'll post to both Phenix and CCP4 BBs.
Where does the crystallographic community stand on deposition of coordinates with riding hydrogens? Explicit H are required for calculating all atom clash scores with Molprobity, and their use frequently gives better geometry (especially at low resolution). Phenix uses explicit riding H for refinement, and outputs these in the refined PDB. Refmac also uses riding H but does not output H coordinates.
While depositing a series of structures refined at 1.4 - 2.75 A with Phenix got the following email from the RCSB, who asked I resupply coordinates without H for two of the structures. Since we can't see H even at 1.4 Å I don't understand why an arbitrary cut off of 1.5 Å was chosen, and also why explicit H atoms used in refinement and geometry validation should be stripped from the file.
FROM RCSB
We encourage depositors not to use hydrogens in the final PDB file for the low resolution structures (> 1.5 A). Please provide an updated PDB file. We request you to use processed PDB file as a starting point for making any corrections to the coordinates and/or re-refinement. --
Mark _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb