Hi Ahmad,
Is this validation for cryo-EM structures or from X-ray/neutron structures?
With cryo-EM maps there is some additional tracking of shifts and that
could be a cause of the problem. Is it possible to send us your input files
(off-list) so that we can investigate?
--
Billy K. Poon
Research Scientist, Molecular Biophysics and Integrated Bioimaging
Lawrence Berkeley National Laboratory
1 Cyclotron Road, M/S 33R0345
Berkeley, CA 94720
Tel: (510) 486-5709
Fax: (510) 486-5909
Web: https://phenix-online.org
On Wed, Jul 17, 2019 at 10:46 AM Ahmad Khalifa
Hello,
After the update, when I open coot from validation with Phenix integration, and navigate to different atoms, clashes, etc, I get moved to an empty space outside of my map and model.
What's going wrong here?
Regards. _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb Unsubscribe: [email protected]